Tornado Series Long Pathlength Gas Cell

Long Pathlength Gas Cells

Various long pathlength gas cell sizes

Based on the White cell principle of multiple light passes between an arangement of reflecting mirrors, Tornado™ series is available the three sizes:

Tornado™ T5 – pathlengths ranging from 1m to 8m in 1m steps

Tornado™ T10 – pathlengths ranging from 2.1m to 10.6m in 1.06m steps

Tornado™ T20 – pathlengths ranging from 2m to 20m in 2m steps

Tornado™ series gas cells are suitable for operation in all modern FT-IR spectrometers using Specac Benchmark™ baseplate provided as standard.

Excellent build quality gas cell

Borosilicate glass body material and anodised aluminium / stainless steel internal and external components provide superior corrosion resistance against a wide range of gases and vapors. Viton® 'O' rings ensure leak-free performance under vacuum and ambient pressures. State-of-the-art optical design combined with gold mirrors ensures the highest possible light throughput giving superior analytical sensitivity.

The supreme, in-built flexibility of the Tornado™ series allows additional mirror carriages to be used in the same body shell, maximising analytical capability and minimising operational costs.

Use KBr or ZnSe gas cell windows

A choice of KBr or ZnSe window materials allows users to make the optimum choice for their applications, and the transfer optics box is equipped with purge ports to allow operation under inert atmospheres. A range of optional features further enhances the flexibility of the Tornado™ range. 

Request a free quote for the Long Pathlength Gas Cell

For a Long Pathlength Gas Cell price, contact us for a free quote.

Read More
  • T5 Gas Cell
  • T10 Gas Cell
  • T20 Gas Cell
  • Resources
Tornado T5
  • Tornado T5 Gas Cell: Glass Body, CaF2 Windows Tornado T5 Gas Cell with Glass Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24205GCFV
  • Tornado T5 Gas Cell: Glass Body, KBr Windows Tornado T5 Gas Cell with Glass Body, KBr Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24205GKFV
  • Tornado T5 Gas Cell: Glass Body, ZnSe Windows Tornado T5 Gas Cell with Glass Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24205GZFV
  • Tornado T5 Gas Cell: Metal Body, CaF2 Windows Tornado T5 Gas Cell with Metal Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24205MCFV
  • Tornado T5 Gas Cell: Metal Body, ZnSe Windows Tornado T5 Gas Cell with Metal Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24205MZFV
 
Tornado T10
  • Tornado T10 Gas Cell: Glass Body, CaF2 Windows Tornado T10 Gas Cell with Glass Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate). GS24210GCFV
  • Tornado T10 Gas Cell: Glass Body, KBr Windows Tornado T10 Gas Cell with Glass Body, KBr Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate). GS24210GKFV
  • Tornado T10 Gas Cell: Glass Body, ZnSe Windows Tornado T10 Gas Cell with Glass Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate). GS24210GZFV
  • Tornado T10 Gas Cell: Metal Body, CaF2 Windows Tornado T10 Gas Cell with Metal Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate). GS24210MCFV
  • Tornado T10 Gas Cell: Metal Body, ZnSe Windows Tornado T10 Gas Cell with Metal Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate). GS24210MZFV
 
Tornado T20
  • Tornado T20 Gas Cell: Glass Body, CaF2 Windows Tornado T20 Gas Cell with Glass Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0, 16.0, 18.0 and 20.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24220GCFV
  • Tornado T20 Gas Cell: Glass Body, KBr Windows Tornado T20 Gas Cell with Glass Body, KBr Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0, 16.0, 18.0 and 20.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24220GKFV
  • Tornado T20 Gas Cell: Glass Body, ZnSe Windows Tornado T20 Gas Cell with Glass Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0, 16.0, 18.0 and 20.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24220GZFV
  • Tornado T20 Gas Cell: Metal Body, CaF2 Windows Tornado T20 Gas Cell with Metal Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0, 16.0, 18.0 and 20.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24220MCFV
  • Tornado T20 Gas Cell: Metal Body, ZnSe Windows Tornado T20 Gas Cell with Metal Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0, 16.0, 18.0 and 20.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24220MZFV
 
Data Sheets
  • Tornado Gas Cells

    Specac Liquid Process Cells are designed for the optical sampling of industrial process fluids in transmission mode using optical fiber interfaces.
User Manuals

Features

  • Wide pathlength range (1m - 20m)
  • Vacuum to 15 p.s.i. operation
  • Ambient temperature operation
  • Borosilicate glass body
  • Anodised components
  • Gold mirrors (protected)
  • Viton 'O' ring seals
  • KBr or ZnSe windows
  • Purgeable transfer optics box
  • Benchmark series baseplate mounting

Optional Features

  • Additional mirror carriage assemblies
  • Vacuum / gas inlet & outlet taps
  • Pressure gauge
  • Desiccant storage caps
  • Purge bellows