Cyclone Series Heatable Long Pathlength Gas Cells

Heatable Long Pathlength Gas Cells

CLICK HERE FOR PRICING

Gas transmission cell in various sizes

Based on the White cell principle of multiple light passes between an arrangement of reflecting mirrors, Cyclone™ gas cells are available in three sizes:

  • Cyclone C2™ – fixed or Variable pathlengths ranging from 0.5m to 2.5m
  • Cyclone C5™ – fixed or Variable pathlengths ranging from 1m to 8m
  • Cyclone C10™ – fixed or Variable pathlengths ranging from 2.1m to 10.6m

Cyclone™ series gas cells are suitable for operation in all modern FT-IR spectrometers using the Specac Benchmark™ baseplate provided as standard.

Excellent build quality

Cells are available as standard with a borosilicate glass body for operation at ambient temperatures and pressures ranging from vacuum to 15 p.s.i. Protected gold mirrors, internal and external components made from nickel-plated aluminium and stainless steel, and Viton® 'O' rings are combined to ensure the highest chemicals compatibility and protection from leaks.

Vacuum / gas inlet and outlet taps, KBr windows and a purgeable transfer optics box further enhance this already highly featured range. 

Upgradeable long pathlength gas cell

Cyclone's™ impressive list of optional features means that any analytical challenge can be met. Variable pathlength mirror carriages, and a range of fixed pathlength mirror carriages can be used within a single gas cell body to greatly enhance analytical flexibility and reduce costs. 

Nickel-plated aluminium bodies can be specified for high pressure operation up to 125 p.s.i, and heating jackets / high stability temperatures up to 200°C.

Purge bellows allow the transfer optics to be used under inert gas atmospheres (e.g. nitrogen) in applications where the elimination of atmospheric H2O and CO2 absorbances is required.

Durable long pathlength FTIR gas cell

To ensure perfect operation and freedom from unwanted impurities, a number of unique features have been incorporated into the design and manufacture of the Cyclone™ series. The cells are completely free from adhesives and all of the Viton® 'O' ring seals are carefully pre-baked to eliminate any contamination from solvents or out-gassing. Internal screws have small bleed holes drilled into them to prevent any trapped pockets of gas causing sample cross contamination.

CE Compliant long pathlength gas cell

All Cyclone series heated gas cell systems are CE compliant ensuring that they can be operated safely at all times under the recommended conditions.

Request a free quote for the Heatable Long Pathlength Gas Cell

For a Heatable Long Pathlength Gas Cell price, contact us for a free quote.

Read More
  • C2 Gas Cell
  • C5 Gas Cell
  • C10 Gas Cell
  • Resources
Cyclone C2: Glass Body
  • Cyclone C2 Gas Cell: Glass Body, CaF2 Windows, Adjustable Pathlength Cyclone C2 Gas Cell with Glass Body, CaF2 Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 2.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24102GCAV
  • Cyclone C2 Gas Cell: Glass Body, CaF2 Windows, Fixed Pathlength Cyclone C2 Gas Cell with Glass Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 0.5, 1.0, 1.5, 2.0 or 2.5 meters) (Specify spectrometer for Benchmark Baseplate). GS24102GCFV
  • Cyclone C2 Gas Cell: Glass Body, KBr Windows, Adjustable Pathlength Cyclone C2 Gas Cell with Glass Body, KBr Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 2.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24102GKAV
  • Cyclone C2 Gas Cell: Glass Body, KBr Windows, Fixed Pathlength Cyclone C2 Gas Cell with Glass Body, KBr Windows, Fixed Pathlength and Viton Seals (specify pathlength from 0.5, 1.0, 1.5, 2.0 or 2.5 meters) (Specify spectrometer for Benchmark Baseplate). GS24102GKFV
  • Cyclone C2 Gas Cell: Glass Body, ZnSe Windows, Adjustable Pathlength Cyclone C2 Gas Cell with Glass Body, ZnSe Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 2.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24102GZAV
  • Cyclone C2 Gas Cell: Glass Body, ZnSe Windows, Fixed Pathlength Cyclone C2 Gas Cell with Glass Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 0.5, 1.0, 1.5, 2.0 or 2.5 meters) (Specify spectrometer for Benchmark Baseplate). GS24102GZFV
Cyclone C2: Metal Body
  • Cyclone C2 Gas Cell: Metal Body, CaF2 Windows, Adjustable Pathlength Cyclone C2 Gas Cell with Metal Body, CaF2 Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 2.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24102MCAV
  • Cyclone C2 Gas Cell: Metal Body, CaF2 Windows, Fixed Pathlength Cyclone C2 Gas Cell with Metal Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 0.5, 1.0, 1.5, 2.0 or 2.5 meters) (Specify spectrometer for Benchmark Baseplate). GS24102MCFV
  • Cyclone C2 Gas Cell: Metal Body, ZnSe Windows, Adjustable Pathlength Cyclone C2 Gas Cell with Metal Body, ZnSe Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 2.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24102MZAV
  • Cyclone C2 Gas Cell: Metal Body, ZnSe Windows, Fixed Pathlength Cyclone C2 Gas Cell with Metal Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 0.5, 1.0, 1.5, 2.0 or 2.5 meters) (Specify spectrometer for Benchmark Baseplate). GS24102MZFV
 
Cyclone C5: Glass Body
  • Cyclone C5 Gas Cell: Glass Body, CaF2 Windows, Adjustable Pathlength Cyclone C5 Gas Cell with Glass Body, CaF2 Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 5.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24105GCAV
  • Cyclone C5 Gas Cell: Glass Body, CaF2 Windows, Fixed Pathlength Cyclone C5 Gas Cell with Glass Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24105GCFV
  • Cyclone C5 Gas Cell: Glass Body, KBr Windows, Adjustable Pathlength Cyclone C5 Gas Cell with Glass Body, KBr Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 5.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24105GKAV
  • Cyclone C5 Gas Cell: Glass Body, KBr Windows, Fixed Pathlength Cyclone C5 Gas Cell with Glass Body, KBr Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24105GKFV
  • Cyclone C5 Gas Cell: Glass Body, ZnSe Windows, Adjustable Pathlength Cyclone C5 Gas Cell with Glass Body, ZnSe Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 5.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24105GZAV
  • Cyclone C5 Gas Cell: Glass Body, ZnSe Windows, Fixed Pathlength Cyclone C5 Gas Cell with Glass Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate). GS24105GZFV
Cyclone C5: Metal Body
  • Cyclone C5 Gas Cell: Metal Body, CaF2 Windows, Adjustable Pathlength Cyclone C5 Gas Cell with Metal Body, CaF2 Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 5.0 meters) (Specify spectrometer for Benchmark Baseplate) GS24105MCAV
  • Cyclone C5 Gas Cell: Metal Body, CaF2 Windows, Fixed Pathlength Cyclone C5 Gas Cell with Metal Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate) GS24105MCFV
  • Cyclone C5 Gas Cell: Metal Body, ZnSe Windows, Adjustable Pathlength Cyclone C5 Gas Cell with Metal Body, ZnSe Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 5.0 meters) (Specify spectrometer for Benchmark Baseplate) GS24105MZAV
  • Cyclone C5 Gas Cell: Metal Body, ZnSe Windows, Fixed Pathlength Cyclone C5 Gas Cell with Metal Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 meters) (Specify spectrometer for Benchmark Baseplate) GS24105MZFV
 
Cyclone C10: Glass Body
  • Cyclone C10 Gas Cell: Glass Body, CaF2 Windows, Adjustable Pathlength Cyclone C10 Gas Cell with Glass Body, CaF2 Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110GCAV
  • Cyclone C10 Gas Cell: Glass Body, CaF2 Windows, Fixed Pathlength Cyclone C10 Gas Cell with Glass Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110GCFV
  • Cyclone C10 Gas Cell: Glass Body, KBr Windows, Adjustable Pathlength Cyclone C10 Gas Cell with Glass Body, KBr Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110GKAV
  • Cyclone C10 Gas Cell: Glass Body, KBr Windows, Fixed Pathlength Cyclone C10 Gas Cell with Glass Body, KBr Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110GKFV
  • Cyclone C10 Gas Cell: Glass Body, ZnSe Windows, Adjustable Pathlength Cyclone C10 Gas Cell with Glass Body, ZnSe Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110GZAV
  • Cyclone C10 Gas Cell: Glass Body, ZnSe Windows, Fixed Pathlength Cyclone C10 Gas Cell with Glass Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110GZFV
Cyclone C10: Metal Body
  • Cyclone C10 Gas Cell: Metal Body, CaF2 Windows, Adjustable Pathlength Cyclone C10 Gas Cell with Metal Body, CaF2 Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110MCAV
  • Cyclone C10 Gas Cell: Metal Body, CaF2 Windows, Fixed Pathlength Cyclone C10 Gas Cell with Metal Body, CaF2 Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110MCFV
  • Cyclone C10 Gas Cell: Metal Body, ZnSe Windows, Adjustable Pathlength Cyclone C10 Gas Cell with Metal Body, ZnSe Windows, Adjustable Pathlength and Viton Seals (supplied with pathlength set at 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110MZAV
  • Cyclone C10 Gas Cell: Metal Body, ZnSe Windows, Fixed Pathlength Cyclone C10 Gas Cell with Metal Body, ZnSe Windows, Fixed Pathlength and Viton Seals (specify pathlength from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.4, 9.5 and 10.6 meters) (Specify spectrometer for Benchmark Baseplate) GS24110MZFV
  • Cyclone C10 Gas Cell gold mirrors on fixed mirror carriage frame assembly Cyclone C10 Gas Cell gold mirrors on fixed mirror carriage frame assembly complete (specify mirror pathlength setting on the frame from 2.1, 3.2, 4.2, 5.3, 6.3, 7.4, 8.5, 9.5 or 10.6 meter options) GS24152-C10
 
Data Sheets
User Manuals

Features

  • Fixed or variable pathlengths
  • 0.5m to 2.5m
  • 1m to 8m
  • 2.1m to 10.6m